Model 0401

Mullin Advantage 
Slider
Model 0402


Structural
AAMA
101/I.S. 2-97
Test
Size
Loads Water Air @
25 mph
DP
H-LC30
44" x 77" 45.0 PSF 4.5 PSF 0.11
CFM/FT



Thermal-NFRC 100-97
U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .49 .49
LoE2/Argon (ClimaTech) .35 .34
LoE/Argon SST .34 .33


Structural
AAMA
101/I.S. 2-97
Test
Size
Loads Water Air @
25 mph
DP
HS-LC35
72" x 54" 60.0 PSF 5.25 PSF 0.15
CFM/FT



Thermal-NFRC 100-97
U-Value U-Value
Size 60" x 36" 72" x 48"
Clear .48 .48
LoE2/Argon (ClimaTech) .32 .30
LoE/Argon SST .30 .29

 

Advantage All-Welded
Double Hung
Model 0601

Advantage All-Welded 
Slider
Model 0602


Structural
AAMA
101/I.S. 2-97
Test
Size
Loads Water Air @
25 mph
DP
H-LC40
44" x77" 60.0 PSF 6.0 PSF 0.18
CFM/FT



Thermal-NFRC 100-97
U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .46 .47
LoE2/Argon (ClimaTech) .31 .30
LoE/Argon SST .29 .28


Structural
AAMA
101/I.S. 2-97
Test
Size
Loads Water Air @
25 mph
DP
HS-LC45
72" x 54" 67.5 PSF 6.75 PSF 0.19
CFM/FT



Thermal-NFRC 100-97
U-Value U-Value
Size 60" x 36" 72" x 48"
Clear .46 .47
LoE2/Argon (ClimaTech) .31 .30
LoE/Argon SST .29 .29

 